Uf-b underground feeder cable, 10/2 awg, 250 ft applications southwire type uf-b cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2008 national electrical code. Uf-b cable may be used underground, including direct burial. Multiple conductor uf-b cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°c (with ampacity limited to that for 60°c conductors) as specified by the national electrical code.
- Uf-b can be used in applications permitted for nmc in section 334.10(b) of the national electrical code
- Voltage rating for uf-b cable is 600 volts
- Specifications southwire type uf-b cable meets or exceeds ul standard 83, ul standard 493, federal specification a-a-59544, and requirements of the national electrical code
- Construction southwire type uf-b cable is manufactured as a 2 conductor cable without a ground wire
- Copper conductors are annealed (soft) copper, solid or compressed stranded
- Phase conductors are polyvinyl chloride (pvc) insulated, nylon jacketed, color coded for identification purposes
- Jacketed with sunlight, moisture and fungus resistant gray pvc.
Product details
- Heat capacity 90 degrees c
- Ampacity 30 amp
- Insulation material Pvc
- Max voltage 600 v
- For use with Wet or dry
- Wire type Uf-b
- Brand Southwire
- Package type Spool
- Number of conductors 2
- Manufacturers part number 13056755
- Wire type description Underground feeder type b
Weights & dimensions
- Length 250 ft
- Gauge 10 ga